Secutron MR-2100 Manual do Operador Página 1

Consulte online ou descarregue Manual do Operador para Redes Secutron MR-2100. Secutron MR-2100 Operator`s manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
OPERATOR’S
MANUAL
Revision 0
Document #: LT-2002
WARNING: This manual contains information on limitations
regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire
manual
should be read carefully.
MR-2100/2200
Fire Alarm Control Unit
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - OPERATOR’S

OPERATOR’SMANUAL Revision 0 Document #: LT-2002WARNING: This manual contains information on limitationsregarding product use and function and informat

Página 2 - Copyrights and Trademarks

MR-2100/2200 Operator’s Manual6the First or Last entry. Once viewing the events, one can look at the next one using the <RightArrow> or the prev

Página 3 - Contents

MR-2100/2200 Operator’s Manual7The Main Menu has the following selections:Status: Displays the current status of various parts of the panel. The follo

Página 4

MR-2100/2200 Operator’s Manual8of occurrence for events occurring at or to the panel. There may be a second screen includinginformation from the datab

Página 5 - 1.0 Unit Operation

MR-2100/2200 Operator’s Manual92.0 Supplementary Information2.1 Condition Codes and Zone NumbersThe History and Archive use the following formats for

Página 6 - 1.3 Status Display

MR-2100/2200 Operator’s Manual10Notes: 1. These zones do not restore.2. Privilege Level 0 generates a restore signal; all others generate a trouble si

Página 7 - 1.6 Operator Keys

MR-2100/2200 Operator’s Manual112.2 Miscellaneous TroublesThis is a list of all possible messages that can be displayed by Miscellaneous Trouble on th

Página 8

MR-2100/2200 Operator’s Manual12BBBBBBAA1234567812List the status of the 8 bell circuits and the 2 auxiliary power circuits. Each column represents on

Página 9 - 1.7 Alarm List

MR-2100/2200 Operator’s Manual13network verify ? illegalThe Network Verify feature has detected that the panel listed is not this panel’s database. Up

Página 12

Copyrights and TrademarksThe installer is to hand over this manual to the owner of the system uponcompletion of work.This manual is copyright 1994 - 2

Página 13 - 2.0 Supplementary Information

© 2005 Secutron, Inc.CanadaSecutron Inc.25 Interchange WayVaughan, ON L4K 5W3Tel: (905)-695-3545Fax: (905)-660-4113USA60 Industrial ParkwayCheektowaga

Página 14

MR-2100/2200 Operator’s ManualiContents1.0 Unit Operation...

Página 15 - 2.2 Miscellaneous Troubles

MR-2100/2200 Operator’s Manualii

Página 16

MR-2100/2200 Operator’s Manual11.0 Unit Operation1.1 Power Up SequenceThe power up sequence of the MR 2100/2200 (hereafter referred to as the MR 2200)

Página 17

MR-2100/2200 Operator’s Manual21.3 Status DisplayThe status display is located in the middle of the main display. It consists of 8 LEDs. The alarm(r

Página 18

MR-2100/2200 Operator’s Manual31.6 Operator KeysThere are 8 operator keys. In the figure below, the keys are located on the lower left and arelabelle

Página 19

MR-2100/2200 Operator’s Manual4SystemResetSystem Reset resets part or all of the system.• The rightmost green LED flashes when the system, or part of

Página 20 - © 2005 Secutron, Inc

MR-2100/2200 Operator’s Manual5Relay Disconnect, Signal Disconnect, Common Disconnect and Test Mode can be made to timeout automatically after 4 hours